ICM282A : Carrier/Bryant Furnace Control Board, ICM Controls

SKU: ICM282A
No Longer Available
360 Spin Image Image of ICM282A

Works with the following brands

SKU:   ICM282A
No Longer Available

ICM Controls ICM282 Furnace Control Board Replacement for Carrier, Bryant.
Replaces Carrier HK42FZ004, HK42FZ007,HK42FZ, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016 & 325878-751.
Control sgas valves, ignitors, blower motors, inducers, humidifiers and air cleaners.
The microprocessor-based design allows for precise timing of the modules, which are designed for 100% gas shutoff in case of ignition failure. Feature reverse polarity protection and secondary brownout voltage protection.

Product Downloads
Installation Instructions
Installation Instructions- 2

  Product Specifications
  Primary Voltage: 98/132 VAC)
  Frequency: 60 Hz
  Cool Fan Off Delay: 5 or 90
  Igniter Current: Ignitor: 5A @ 120 VAC
  Cool Blower: 10A 2 HP 240 VAC
  Heat: 5A 1/2 HP 240 VAC
  Inducer Motor: 4A FLA-8.0 LRA @ 120 VAC
  Gas Valve: 1.5A @ 30 VAC
  Has 360 Photos: Yes

 

Replaces Old Numbers:   13-NYZ1-L4BJ, 24-ICM282, 800442002828, B00441X9H2, ICM282